Till Örebro universitet

oru.seÖrebro universitets publikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Calibrating distance sensors for terrestrial applications without groundtruth information
Luleå University of Technology, Luleå, Sweden. (Mobile Robotics and Olfaction Lab)ORCID-id: 0000-0001-6868-2210
Luleå University of Technology, Luleå, Sweden.
Luleå University of Technology, Luleå, Swede.
2017 (Engelska)Ingår i: IEEE Sensors Journal, ISSN 1530-437X, E-ISSN 1558-1748, Vol. 17, nr 12, s. 3698-3709Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

This paper describes a new calibration procedure for distance sensors that does not require independent sources of groundtruth information, i.e., that is not based on comparing the measurements from the uncalibrated sensor against measurements from a precise device assumed as the groundtruth. Alternatively, the procedure assumes that the uncalibrated distance sensor moves in space on a straight line in an environment with fixed targets, so that the intrinsic parameters of the statistical model of the sensor readings are calibrated without requiring tests in controlled environments, but rather in environments where the sensor follows linear movement and objects do not move. The proposed calibration procedure exploits an approximated expectation maximization scheme on top of two ingredients: an heteroscedastic statistical model describing the measurement process, and a simplified dynamical model describing the linear sensor movement. The procedure is designed to be capable of not just estimating the parameters of one generic distance sensor, but rather integrating the most common sensors in robotic applications, such as Lidars, odometers, and sonar rangers and learn the intrinsic parameters of all these sensors simultaneously. Tests in a controlled environment led to a reduction of the mean squared error of the measurements returned by a commercial triangulation Lidar by a factor between 3 and 6, comparable to the efficiency of other state-of-the art groundtruth-based calibration procedures. Adding odometric and ultrasonic information further improved the performance index of the overall distance estimation strategy by a factor of up to 1.2. Tests also show high robustness against violating the linear movements assumption.

Ort, förlag, år, upplaga, sidor
IEEE, 2017. Vol. 17, nr 12, s. 3698-3709
Nyckelord [en]
Expectation maximization, distance sensors, intrinsic sensors calibration, heteroscedastic models, simultaneous sensors calibration, triangulation lidars, ultrasonic sensors, odometry
Nationell ämneskategori
Reglerteknik Elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:oru:diva-90265DOI: 10.1109/JSEN.2017.2697850ISI: 000402123400012Scopus ID: 2-s2.0-85021749952OAI: oai:DiVA.org:oru-90265DiVA, id: diva2:1535282
Anmärkning

Funding Agencies:

Norrbottens Forskningsråd  

University of Baghdad 

Tillgänglig från: 2021-03-08 Skapad: 2021-03-08 Senast uppdaterad: 2021-03-10Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Alhashimi, Anas

Sök vidare i DiVA

Av författaren/redaktören
Alhashimi, Anas
I samma tidskrift
IEEE Sensors Journal
ReglerteknikElektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 145 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf