Till Örebro universitet

oru.seÖrebro universitets publikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Quality control of flow cytometry data analysis for evaluation of minimal residual disease in bone marrow from acute leukemia patients during treatment
Department of Pathology and Cytology, Karolinska University Hospital, Solna, Sweden.
Department of Clinical Chemistry and Hematology, Kuopio University Hospital, Kuopio, Finland.
Department of Pathology, Rikshospitalet-Radiumhospitalet-HF, Oslo, Norway.
Department of Pathology, Örebro University Hospital (USÖ), Örebro, Sweden.
Visa övriga samt affilieringar
2009 (Engelska)Ingår i: Journal of Pediatric Hematology/Oncology, ISSN 1077-4114, E-ISSN 1536-3678, Vol. 31, nr 6, s. 406-15Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Low levels of leukemia cells in the bone marrow, minimal residual disease (MRD), are considered to be a powerful indicator of treatment response in acute lymphatic leukemia (ALL). A Nordic quality assurance program, aimed on standardization of the flow cytometry MRD analysis, has been established before implementation of MRD at cutoff level 10 as one of stratifying parameters in next Nordic Society of Pediatric Hematology and Oncology (NOPHO) treatment program for ALL. In 4 quality control (QC) rounds 15 laboratories determined the MRD levels in 48 follow-up samples from 12 ALL patients treated according to NOPHO 2000. Analysis procedures were standardized. For each QC round a compact disc containing data in list-mode files was sent out and results were submitted to a central laboratory. At cutoff level 10, which will be applied for clinical decisions, laboratories obtained a high concordance (91.6%). If cutoff level 10 was applied, the concordance would be lower (85.3%). The continuing standardization resulted in better concordance in QC3 and QC4 compared with QC1 and QC2. The concordance was higher in precursor B as compared with T-cell ALL. We conclude that after standardization, flow cytometry MRD detection can be reliably applied in international, multicenter treatment protocols.

Ort, förlag, år, upplaga, sidor
Lippincott Williams & Wilkins, 2009. Vol. 31, nr 6, s. 406-15
Nationell ämneskategori
Hematologi
Identifikatorer
URN: urn:nbn:se:oru:diva-110578DOI: 10.1097/MPH.0b013e3181a1c0e8PubMedID: 19648789Scopus ID: 2-s2.0-67651205898OAI: oai:DiVA.org:oru-110578DiVA, id: diva2:1823756
Tillgänglig från: 2024-01-03 Skapad: 2024-01-03 Senast uppdaterad: 2026-01-16Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Axelsson, Susanne

Sök vidare i DiVA

Av författaren/redaktören
Axelsson, Susanne
I samma tidskrift
Journal of Pediatric Hematology/Oncology
Hematologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 58 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf