Till Örebro universitet

oru.seÖrebro universitets publikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A membrane protein based biosensor: use of a phosphate--H+ symporter membrane protein (Pho84) in the sensing of phosphate ions
Department of Biotechnology, Lund University, Lund, Sweden; School of Natural Sciences, Linnaeus University, Kalmar, Sweden.
School of Natural Sciences, Linnaeus University, Kalmar, Sweden.ORCID-id: 0000-0002-0381-251X
Department of Biotechnology, Lund University, Lund, Sweden.
Department of Fermentation, Technology and Bioengineering, Central Food Technology Research Institute, Mysore, India.
Visa övriga samt affilieringar
2011 (Engelska)Ingår i: Biosensors & bioelectronics, ISSN 0956-5663, E-ISSN 1873-4235, Vol. 27, nr 1, s. 58-63Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

A label free biosensor for direct detection of inorganic phosphate based on potential-step capacitance measurements has been developed. The high-affinity Pho84 plasma membrane phosphate/proton symporter of Saccharomyces cerevisiae was used as a sensing element. Heterologously expressed and purified Pho84 protein was immobilized on a self-assembled monolayer (SAM) on a capacitance electrode. Changes in capacitance were recorded upon exposure to phosphate compared to the control substance, phosphate analogue methylphosphonate. Hence, even without the explicit use of lipid membranes, the Pho84 membrane protein could retain its capacity of selective substrate binding, with a phosphate detection limit in the range of the apparent in vivo K(m). A linear increase in capacitance was monitored in the phosphate concentration range of 5-25 μM. The analytical response of the capacitive biosensor is in agreement with that the transporter undergoes significant conformational changes upon exposure to inorganic phosphate, while exposure to the analogue only causes minor responses.

Ort, förlag, år, upplaga, sidor
Elsevier, 2011. Vol. 27, nr 1, s. 58-63
Nyckelord [en]
Capacitive biosensor, Membrane protein, Pho84, Phosphate, Symporter
Nationell ämneskategori
Biokemi Molekylärbiologi Analytisk kemi
Identifikatorer
URN: urn:nbn:se:oru:diva-112530DOI: 10.1016/j.bios.2011.06.024ISI: 000295953300009PubMedID: 21782409Scopus ID: 2-s2.0-79960923460OAI: oai:DiVA.org:oru-112530DiVA, id: diva2:1846303
Forskningsfinansiär
Sida - Styrelsen för internationellt utvecklingssamarbeteTillgänglig från: 2024-03-22 Skapad: 2024-03-22 Senast uppdaterad: 2025-02-20Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Samyn, Dieter R.

Sök vidare i DiVA

Av författaren/redaktören
Samyn, Dieter R.
I samma tidskrift
Biosensors & bioelectronics
BiokemiMolekylärbiologiAnalytisk kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 111 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf