Till Örebro universitet

oru.seÖrebro universitets publikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
One-year Outcomes of the MODULAR ATP Trial: A Novel Leadless Pacemaker in Wireless Communication with a Subcutaneous Implantable Cardioverter-defibrillator
Emory University, Atlanta, GA, USA.
Mount Sinai Fuster Heart Hospital, New York, NY, USA.
University Hospital Southampton, Southampton, United Kingdom.
Honor Health, Scottsdale, AZ, USA.
Visa övriga samt affilieringar
2026 (Engelska)Ingår i: Circulation: Arrhythmia and Electrophysiology, ISSN 1941-3149, E-ISSN 1941-3084, Vol. 19, nr 1, artikel-id e014395Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background: MODULAR ATP (antitachycardia pacing), a multicenter, international trial, assesses a modular cardiac rhythm management system (mCRM): a subcutaneous implantable cardioverter-defibrillator (S-ICD) in wireless communication with a leadless pacemaker (LP) capable of pace-terminating ventricular tachycardia (VT).

Methods: Enrolees had one or more clinical risk factors for VT and did not require chronic pacing. Complications included pre-specified major LP system- and procedure-related complications, and any complication related to the LP, S-ICD, implantation, or study protocol. Survival analysis was performed to identify complication-free rates, therapy delivery, and all-cause mortality.

Results: The 297 patients enrolled had an ejection fraction 35±13%, 43% secondary prevention indications, and 59% with prior ventricular arrhythmias (VA). Of 286 patients undergoing LP implantation (100% success), 251 patients completed 12-month follow-up. Mortality rate was 6%, with none related to the implant procedure. Median follow-up duration was 23.4 months (interquartile range: 17.9-28.1). The LP major complication-free rate was 97.2%, exceeding the performance goal. The overall LP+S-ICD system-related complication-free rate was 88.5%. Appropriate tachyarrhythmia-therapy (ATP+shock) rates were 14.4% and appropriate shock rates were 8.5%. Inappropriate total tachyarrhythmia therapy was 9.5% of which 8.5% were shocks. ATP was 67.3% successful in terminating VA episodes and accelerated VAs in 10.1% of episodes. Overall therapy burden (ATP+shock) was 96/100 patient-years of which 44/100 patient-years was for shock delivery.

Conclusions: One-year outcomes of the first modular pacing-defibrillator system reveal low system and LP complication rates and good ATP efficacy rates suggesting that the mCRM is a viable alternative to single-chamber ICDs using low-energy pacing capability without the need for transvenous leads.

Ort, förlag, år, upplaga, sidor
Lippincott Williams & Wilkins, 2026. Vol. 19, nr 1, artikel-id e014395
Nyckelord [en]
bradycardiata, chycardia defibrillators
Nationell ämneskategori
Kardiologi och kardiovaskulära sjukdomar
Identifikatorer
URN: urn:nbn:se:oru:diva-125015DOI: 10.1161/CIRCEP.125.014395ISI: 001667084800002PubMedID: 41231774OAI: oai:DiVA.org:oru-125015DiVA, id: diva2:2013779
Tillgänglig från: 2025-11-14 Skapad: 2025-11-14 Senast uppdaterad: 2026-01-29Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Person

Blomström-Lundqvist, Carina

Sök vidare i DiVA

Av författaren/redaktören
Blomström-Lundqvist, Carina
Av organisationen
Institutionen för medicinska vetenskaperRegion Örebro län
I samma tidskrift
Circulation: Arrhythmia and Electrophysiology
Kardiologi och kardiovaskulära sjukdomar

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 49 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf