Till Örebro universitet

oru.seÖrebro universitets publikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
The effect of anatomical noise on perception of low contrast in intra-oral radiographs: an in vitro study
Department of Oral and Maxillofacial Radiology, Faculty of Odontology, Malmö University, Malmö, Sweden; Department of Oral Radiology, Postgraduate Dental Education Center, Region Örebro County, Örebro, Sweden.
Department of Oral and Maxillofacial Radiology, Faculty of Odontology, Malmö University, Malmö, Sweden; Department of Radiation Physics, Skåne University Hospital, Malmö, Sweden.
Örebro universitet, Institutionen för medicinska vetenskaper. Postgraduate Dental Education Center, Region Örebro County, Örebro, Sweden.ORCID-id: 0000-0003-1106-4192
Department of Oral and Maxillofacial Radiology, Faculty of Odontology, Malmö University, Malmö, Sweden.
2016 (Engelska)Ingår i: Dento-Maxillo-Facial Radiology, ISSN 0250-832X, E-ISSN 1476-542X, Vol. 45, nr 4, artikel-id 20150402Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Objectives: Radiographic images suffer from varying amounts of noise. The most studied and discussed of these is random noise. However, recent research has shown that the projected anatomy contributes substantially to noise, especially when detecting low-contrast objects in the images. Our aim, therefore, was to evaluate the extent to which overprojected anatomical noise affects the detection of low-contrast objects in intra-oral images.

Methods: Our study used four common sensor models. With each sensor, we took four series of images, three series with and one series without an anatomical phantom present. In each series, we exposed a low-contrast phantom at 18 different exposure times using a standardized method. 4 observers evaluated all 288 images.

Results: The low-contrast characteristics differed substantially when imaging low contrast on a homogeneous background compared with imaging low contrast when an anatomical phantom was present. For three of the sensors, optimal exposure times for low-contrast imaging were found, while the fourth sensor displayed a completely different behaviour.

Conclusions: Calibrating the low-contrast properties of an imaging system using low-contrast objects on a homogeneous background is not recommended. On an anatomical background, low-contrast properties are completely different, and these will mimic the clinical situation much more closely, directing the operator how to best use the system. There is a clear demand for further research on this subject.

Ort, förlag, år, upplaga, sidor
London, United Kingdom: British Institute of Radiology , 2016. Vol. 45, nr 4, artikel-id 20150402
Nyckelord [en]
Contrast sensitivity, dental, digital, radiography
Nationell ämneskategori
Radiologi och bildbehandling Odontologi
Forskningsämne
Radiologi
Identifikatorer
URN: urn:nbn:se:oru:diva-49439DOI: 10.1259/dmfr.20150402ISI: 000376216200001PubMedID: 26891747Scopus ID: 2-s2.0-84989809404OAI: oai:DiVA.org:oru-49439DiVA, id: diva2:913634
Tillgänglig från: 2016-03-22 Skapad: 2016-03-22 Senast uppdaterad: 2023-12-08Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Svenson, Björn

Sök vidare i DiVA

Av författaren/redaktören
Svenson, Björn
Av organisationen
Institutionen för medicinska vetenskaper
I samma tidskrift
Dento-Maxillo-Facial Radiology
Radiologi och bildbehandlingOdontologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 533 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf