To Örebro University

oru.seÖrebro University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
The Diabetes Technology Society Error Grid and Trend Accuracy Matrix for Glucose Monitors
Diabetes Research Institute, Mills-Peninsula Medical Center, San Mateo, CA, USA.
Örebro University, School of Medical Sciences.ORCID iD: 0000-0003-1025-1682
University of California San Francisco, San Francisco, CA, USA.
Number of Authors: 942024 (English)In: Journal of Diabetes Science and Technology, E-ISSN 1932-2968, Vol. 18, no 6, p. 1346-1361Article in journal (Refereed) Published
Abstract [en]

INTRODUCTION: An error grid compares measured versus reference glucose concentrations to assign clinical risk values to observed errors. Widely used error grids for blood glucose monitors (BGMs) have limited value because they do not also reflect clinical accuracy of continuous glucose monitors (CGMs).

METHODS: Diabetes Technology Society (DTS) convened 89 international experts in glucose monitoring to (1) smooth the borders of the Surveillance Error Grid (SEG) zones and create a user-friendly tool-the DTS Error Grid; (2) define five risk zones of clinical point accuracy (A-E) to be identical for BGMs and CGMs; (3) determine a relationship between DTS Error Grid percent in Zone A and mean absolute relative difference (MARD) from analyzing 22 BGM and nine CGM accuracy studies; and (4) create trend risk categories (1-5) for CGM trend accuracy.

RESULTS: The DTS Error Grid for point accuracy contains five risk zones (A-E) with straight-line borders that can be applied to both BGM and CGM accuracy data. In a data set combining point accuracy data from 18 BGMs, 2.6% of total data pairs equally moved from Zones A to B and vice versa (SEG compared with DTS Error Grid). For every 1% increase in percent data in Zone A, the MARD decreased by approximately 0.33%. We also created a DTS Trend Accuracy Matrix with five trend risk categories (1-5) for CGM-reported trend indicators compared with reference trends calculated from reference glucose.

CONCLUSION: The DTS Error Grid combines contemporary clinician input regarding clinical point accuracy for BGMs and CGMs. The DTS Trend Accuracy Matrix assesses accuracy of CGM trend indicators.

Place, publisher, year, edition, pages
Diabetes Technology Society , 2024. Vol. 18, no 6, p. 1346-1361
Keywords [en]
Accuracy, blood glucose, continuous glucose monitoring, error grid, glucose trend, surveillance
National Category
Endocrinology and Diabetes
Identifiers
URN: urn:nbn:se:oru:diva-116552DOI: 10.1177/19322968241275701ISI: 001348255900010PubMedID: 39369312Scopus ID: 2-s2.0-85205866150OAI: oai:DiVA.org:oru-116552DiVA, id: diva2:1903742
Note

This study was supported by a grant from Abbott Diabetes Care.

Available from: 2024-10-07 Created: 2024-10-07 Last updated: 2025-01-14Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Jendle, Johan

Search in DiVA

By author/editor
Jendle, Johan
By organisation
School of Medical Sciences
In the same journal
Journal of Diabetes Science and Technology
Endocrinology and Diabetes

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 147 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf