Evaluation of the impact of reduced scan field-of-view (SFOV) on CT radiation dose and image quality in a chest CT – a phantom study
Örebro University, School of Health Sciences.
2022 (English)Independent thesis Advanced level (degree of Master (One Year)), 10 credits / 15 HE creditsStudent thesisAlternative title
Utvärdering av effekten av reducerat skanningsfält (SFOV) på stråldos och bildkvalitet i en DT-thoraxundersökning - en fantomstudie (Swedish)
Abstract [en]

Background: Technical development of image detectors and dose-reduction techniques in computed tomography (CT) have contributed to reduce radiation dose for patient and staff. The scan field of view (SFOV) generally affects the radiation dose the patient will beexposed. The aim of this phantom study is to assess how radiation dose and image quality are affected by changing the SFOV from 50cm to 32cm on a CT chest examination Material and methods: A chest phantom and CatPhan 504 phantom were scanned with different SFOV (50cm and 32cm SFOV) to assess variation in CTDIvol and image quality between the two SFOV. A RaySafe CT-sensor was scanned with both SFOV at different position in the gantry to assess the variation in absorbed dose between the two SFOV. Image quality between the two SFOV was compared for the chest phantom and the CatPhan 504. Results: The difference in CTDIvol for the two SFOVwas not statistically significant p>0,05 (p=0,89 for the chest-phantom and p=0,96 for the CatPhan 504). No difference in image quality was found between the two SFOV and for both phantoms. The absorbed dose measured with RaySafe CT sensor shows that the absorded dose decreases from the center to the periphery for both SFOV. There was a difference in standard error of the mean between the two scan methods Discussion: Different bowtie filters were chosen automatically by the CT for different SFOV. This might affect the tube-current modulation and the reduction of the radiation dose in the periphery due to the use of different bowtie-filters. Further studies are needed where restricted SFOV is used in combination with other methods for reducing dose, such as dynamic bowtie filters and automatic exposure can be recommended.  Keywords: Computed tomography, CT, Scan field-of-view, SFOV, Radiation dose 

Place, publisher, year, edition, pages
2022.
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:oru:diva-100811OAI: oai:DiVA.org:oru-100811DiVA, id: diva2:1689810
Subject / course
Medicine
Supervisors
Examiners
Available from: 2022-08-24 Created: 2022-08-24 Last updated: 2022-08-24Bibliographically approved

Open Access in DiVA

fulltext(884 kB)333 downloads
File information
File name FULLTEXT01.pdfFile size 884 kBChecksum SHA-512
eacc6fb35be02b3d82c2b161ec4f89f4a44e46c875b8008cd726a22b5846fbe569e6dbde40c42002b382c7e725b69b5d04a932b388a9febcec6bcaaebd101114
Type fulltextMimetype application/pdf

By organisation
School of Health Sciences
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 333 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1402 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf