To Örebro University

oru.seÖrebro University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Nivåbedömning i oktavband: Är det rimligt vid hörapparatanpassning?
Örebro University, School of Health Sciences.
Örebro University, School of Health Sciences.
2023 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Level evaluation in octave bands: Is it reasonable when fitting hearing aids? (English)
Abstract [sv]

Bakgrund: Finjusteringar av hörapparatens förstärkning görs för att validera förstärkningen. Patientens förmåga att kategorisera ljudbilden ligger till grund för de justeringar som görs.

Syfte: Att utvärdera en praktiknära metod för finjustering av hörapparater.

Metod: Deltagarna (N = 18) fick lyssna på och bedöma ljudbilden för ett talmaterial med slumpade nivåmodifieringar i oktavbandet 4 kHz. Försöksledaren korrigerade ljudbilden utifrån deltagarnas nivåbedömning, till dess att deltagarna upplevde att ljudbilden var naturlig. Deltagarna fick efter halva undersökningen, som intervention, lyssna på en genomgång som förklarade och jämförde de olika ljudbilderna.

Resultat: Deltagarnas nivåbedömningar ledde till korrigeringar i oktavbandet som var statistiskt signifikanta, men en normalisering av oktavbandet uppnåddes inte. Efter genomgången kunde fler nivåmodifikationer korrigeras med en statistiskt signifikant skillnad. Nivåmodifikationer som kan kategoriseras som metalliska/skarpa ledde oftare till en statistiskt signifikant korrigering, än nivåmodifikationer som kan kategoriseras som otydliga/dova.

Slutsatser: Om finjusteringar av hörapparaterna görs, bör audionomen ha klart för sig att det kan behövas större nivåförändringar i större frekvensband, för att patienten ska ha möjlighet att uppleva en skillnad i ljudbilden i en klinisk miljö.

Abstract [en]

Background: Fine-tuning of the hearing aid amplification is done to validate the amplification. The patient's ability to describe the sound quality lays as a foundation for the fine-tuning.

Aim: To evaluate a practice-oriented method for fine-tuning hearing aids.

Methods: The participants (N = 18) listened to and evaluated the sound quality for a speech-material with randomized level modifications in the octave band 4 kHz. The sound quality was adjusted according to the participants' evaluation, until a normalized sound quality was perceived by the participants. Halfway through the examination the participants, as an intervention, listened to a briefing which explained and compared differences in the different sound qualities.

Results: The participants level evaluation led to adjustment in the octave band that was statistically significant, but a normalization of the octave band could not be achieved. After the briefing a larger number of level modifications were adjusted with a statistical significance. Level modifications which were categorized as metallic/sharp more often led to a statistically significant adjustment compared to level modifications categorized as unclear/dull.

Conclusions: If fine-tuning of hearing aids is done, the audiologist should be aware that bigger level adjustment in broad bands might be needed, for the patient to be able to notice a difference in sound quality in a clinical setting.

Place, publisher, year, edition, pages
2023. , p. 38
Keywords [en]
hearing aid fitting, hearing aid fine-tuning, sound quality adjustment, level increment, level decrement, octave band, level discrimination
Keywords [sv]
hörapparatanpassning, finjustering av hörapparater, justering av ljudkvalitet, nivåökning, nivåsänkning, oktavband, nivådiskriminering
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:oru:diva-106044OAI: oai:DiVA.org:oru-106044DiVA, id: diva2:1759396
Subject / course
Audiology
Supervisors
Examiners
Available from: 2023-05-25 Created: 2023-05-25 Last updated: 2024-03-04Bibliographically approved

Open Access in DiVA

Nivåbedömning i oktavband: Är det rimligt vid hörapparatanpassning?(817 kB)114 downloads
File information
File name FULLTEXT01.pdfFile size 817 kBChecksum SHA-512
cf058d39f2947085cdb39791e0d362581cdb9f6f13b57bf5e31029ea45f4f50973d5ce8ebc7186249829107197ce32bc2d7919f0aade46d212f4d3ea1529f245
Type fulltextMimetype application/pdf

By organisation
School of Health Sciences
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 115 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 172 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf