Jämförelse av stationär och mobil spirometriutrustning vid utförandet av dynamisk spirometri: En metodjämförelse mellan Vyntus™ One och Aiocare™ Vyaire
Örebro University, School of Health Sciences.
2023 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Comparison of stationary and mobile spirometry equipment while performing dynamic spirometry : A method comparison between Vyntus™ One and Aiocare™ Vyaire (English)
Abstract [sv]

Introduktion 

Genom dynamisk spirometri går det att beräkna kvoten mellan forcerad exspiratorisk volym under en sekund och forcerad vitalkapacitet (FEV1/FVC) där ett värde på ≤0,7 tyder på obstruktiv lungsjukdom. Mobil spirometriutrustning skulle kunna möjliggöra tidigare diagnostisering av obstruktiva lungsjukdomar men även fungera som ett kostnadseffektivt alternativ vid enklare undersökningar. Syftet med studien var att jämföra resultat erhållna vid dynamisk spirometri utförd på en stationär respektive en mobil spirometriutrustning.

Material och metod 

I studien deltog totalt 36 försökspersoner. Data samlades in mellan februari-mars 2023 och bestod av FVC och FEV1 erhållna från dynamisk spirometri på Vyntus™ One (stationär spirometriutrustning) och Aiocare™ Vyaire (mobil spirometriutrustning). Ett parat t-test (signifikansnivå 0,05) utfördes för att avgöra om det förelåg någon signifikant systematisk skillnad för data mellan de båda utrustningarna och förekomsten av slumpfel illustrerades med Bland-Altman-diagram. Intraklasskorrelationskoefficient (ICC) beräknades för samtliga variabler.

Resultat och slutsats 

En mycket god korrelation mellan utrustningarna förelåg med ett ICC>0.9 för samtliga variabler. Ingen systematisk skillnad kunde påvisas för uppmätt FVC, FEV1 eller kvoten FEV1/FVC mellan Vyntus™ One och Aiocare™ Vyaire (p >0,05) och slumpfelet bedömdes acceptabelt.

Abstract [en]

Introduction 

Dynamic spirometry enables calculating the ratio of forced expiratory volume under one second and forced vital capacity (FEV1/FVC) where ≤0,7 suggests obstructive lung disease. Mobile spirometer equipment could assist in earlier detection of obstructive lung diseases, but also function as a cost-efficient alternative. The purpose of the study is to compare results obtained with dynamic spirometry performed on a stationary and a mobile spirometry equipment.

Material and method 

A total of 36 subjects participated in the study. Data collected between February-March 2023 consisted of FVC and FEV1 obtained from dynamic spirometry on Vyntus™ One (stationary spirometry equipment) and Aiocare™ Vyaire (mobile spirometry equipment). A paired t-test (0,05 level of significance) determined if there was any significant systematic difference between data from the two types of equipment and the magnitude of sampling error was visualized by Bland-Altman plots. Intraclass correlation coefficient (ICC) was calculated for all variables.

Result and conclusion 

Excellent correlation with ICC>0,9 for all variables. There was no significant difference for measured FVC, FEV1 or FEV1/FVC between Vyntus™ One and Aiocare™ Vyaire (p >0,05) and the sampling error was considered acceptable.

Place, publisher, year, edition, pages
2023.
Keywords [en]
Dynamic spirometry, mobile spirometry equipment, forced vital capacity (FVC), forced expiratory volume under one secund (FEV1)
Keywords [sv]
Dynamisk spirometri, mobil spirometriutrustning, forcerad vitalkapacitet (FVC), forcerad exspiratorisk volym under en sekund (FEV1)
National Category
Biomedical Laboratory Science/Technology
Identifiers
URN: urn:nbn:se:oru:diva-106678OAI: oai:DiVA.org:oru-106678DiVA, id: diva2:1777241
Subject / course
Biomedicinsk laboratorievetenskap
Supervisors
Examiners
Available from: 2023-06-29 Created: 2023-06-29 Last updated: 2023-06-29Bibliographically approved

Open Access in DiVA

Jämförelse av stationär och mobil spirometriutrustning vid utförandet av dynamisk spirometri En metodjämförelse mellan Vyntus™ One och Aiocare™ Vyaire(566 kB)274 downloads
File information
File name FULLTEXT01.pdfFile size 566 kBChecksum SHA-512
05085d9f5b9d98341dc32af59a6ad39ae2f01f150d758c68cc3c284acc19dd86fbaff3195bc3d8df4c78474e65579869912f9692ddf025c04a3aa272b9cfaea1
Type fulltextMimetype application/pdf

By organisation
School of Health Sciences
Biomedical Laboratory Science/Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 276 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 438 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf