Reliabilitet hos förmaksspecifika elektrokardiografiska parametrar i en hjärtfrisk population
2024 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE credits
Student thesisAlternative title
Reliability of atrial-specific electrocardiographic parameters in a heart healthy population (English)
Abstract [sv]
Elektrokardiografi (EKG) är en metod för att registrera hjärtats elektriska aktivitet, används för att utreda eventuella patologier i hjärtats retledningssystem. Studien fokuserar på parametrar som är relaterade till förmaksdepolarisationen som på ett EKG speglas av P-vågen. Syftet var att utvärdera och analysera reliabiliteten vid upprepade mätningar av specifika EKG-parametrar samt att undersöka eventuella könsskillnader i en hjärtfrisk population. Studien bestod av 45 forskningspersoner. EKG-undersökningen utfördes vid ett tillfälle, därefter mättes EKG-parametrar manuellt på en EKG-utskrift. För att utvärdera mätningarnas reliabilitet inom och mellan observatörer användes intraklasskorrelationskoefficienten (ICC) och för analys av könsskillnader oparat t-test. ICC-värdet var ≥ 0,9 för P-vågsarea och PWAII. För PDV1 och II samt PTFV1 var ICC mellan 0,75–0,9. För PWPTII var ICC mellan 0,5–0,75, medan det var ≤ 0,5 för PWAV1. ICC varierade mellan 0,5–0,75 för PWPTV1. En jämförelse mellan manuell och automatisk tolkning av EKG-parametrarna visade god överensstämmelse. Det förelåg inga statistiskt signifikanta könsskillnader hos någon av EKG-parametrarna (p>0,05). Majoriteten av EKG-parametrar uppvisade god till utmärkt pålitlighet vid upprepande mätningar både inom och mellan observatörer. Det fanns även god överensstämmelse mellan manuell tolkning och automatisk algoritmtolkning. Inga signifikanta könsskillnader i EKG-parametrar kunde påvisas.
Abstract [en]
Electrocardiography (ECG) is a method of recording the heart's electrical activity, used to investigate possible pathologies in the heart's conduction system. Study concentrates on parameters related to atrial depolarization as reflected P-wave on an ECG. The aim is to evaluate and analyze the reliability of repeated measurements of these ECG parameters and to explore potential gender differences in a heart-healthy population. The study involved 45 participants. ECG was performed on one occasion. ECG parameters were measured manually on an ECG printout. To assess the reliability of the measurements within and between observers and analysis of gender differences, intraclass correlation coefficient (ICC) and unpaired t-test were used. ICC value was ≥ 0.9 for P-wave area and PWAII. For PDV1 and II as well as PTFV1, the ICC was between 0,75–0,9. For PWPTII was ICC between 0,5–0,75, while it was ≤ 0.5 for PWAV1. ICC varied between 0.5–0.75 for PWPTV1. Good agreement showed between manual and automatic interpretation. There were no significant gender differences in any of the ECG parameters (p-value > 0,05). The majority of ECG parameters showed good to excellent reliability in repeated measurements both within and between observers. A good agreement showed between the manual and automatic algorithm interpretation. There were no significant gender differences in ECG parameters.
Place, publisher, year, edition, pages
2024. , p. 34
Keywords [en]
Electrocardiography, cardiac electrophysiology, atrial fibrillation, heart atria
Keywords [sv]
Elektrokardiografi, hjärtelektrofysiologi, förmaksflimmer, hjärtförmak
National Category
Biomedical Laboratory Science/Technology