To Örebro University

oru.seÖrebro University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Airborne trichloramine in indoor swimming pools in Sweden
School of Public Health and Community Medicine, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
Department of Public Health and Clinical Medicine, Umeå University, Umeå, Sweden.
School of Public Health and Community Medicine, Institute of Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
Örebro University, School of Medical Sciences. Örebro University Hospital. Department of Occupational and Environmental Medicine.
Show others and affiliations
2024 (English)In: Journal of Occupational and Environmental Hygiene, ISSN 1545-9624, E-ISSN 1545-9632, Vol. 21, no 11, p. 805-816Article in journal (Refereed) Published
Abstract [en]

Trichloramine is a disinfection by-product in chlorinated swimming pools. It can evaporate into the air and irritate eyes and airways among swimmers and pool workers. This study aimed to evaluate airborne concentrations of trichloramine in different types of indoor swimming pools. Altogether, 72 swimming pools across Sweden were included; 36 exercise pools, 16 instruction pools, seven adventure pools, and 13 rehabilitation pools. In total, 167 sampling sessions were performed with the majority (N = 91) conducted in public exercise pools. Repeated sampling sessions on different days were performed within all pool categories. Airborne trichloramine was measured stationary by the poolside using active sampling on quartz filters. In total, 434 air samples were collected. The geometric mean (GM) concentration of trichloramine for the exercise pools was 0.12 mg/m3 (range GMpool: 0.02-0.29 mg/m3) and for about 30% the GMpool exceeded the Swedish public health guideline value (0.2 mg/m3). The geometric mean for instruction pools was 0.18 mg/m3 and for adventure pools 0.20 mg/m3. Trichloramine concentrations were statistically significantly lower in rehabilitation pools (GM: 0.03 mg/m3) compared with the other pool categories. A statistically significant effect of time of the day for sampling was found for the exercise and instruction pools, with higher trichloramine levels during evenings compared with mornings and afternoons. For the rehabilitation pools, trichloramine was significantly higher during the cold season compared with the warm season. Variability in trichloramine concentrations was attributed to between-pool as well as within-pool variances. The within-pool variability encourages a repeated sampling strategy to capture the variation between different days. These findings have implications for exposure assessment in epidemiological studies as well as for indoor air quality monitoring. Trichloramine can cause acute irritative effects at elevated levels, and since trichloramine concentrations may differ depending on the time of the day it is recommended that full-day stationary measurements are supplemented with short-term samplings to capture these variations.

Place, publisher, year, edition, pages
Taylor & Francis, 2024. Vol. 21, no 11, p. 805-816
Keywords [en]
Determinants, disinfection by-products, exposure assessment, indoor air quality, public pool, variability
National Category
Occupational Health and Environmental Health
Identifiers
URN: urn:nbn:se:oru:diva-117016DOI: 10.1080/15459624.2024.2400231ISI: 001340727400001PubMedID: 39442164Scopus ID: 2-s2.0-8520744747OAI: oai:DiVA.org:oru-117016DiVA, id: diva2:1908098
Funder
Swedish Research Council FormasForte, Swedish Research Council for Health, Working Life and WelfareSödra sjukvårdsregionen, FORSS-9026Available from: 2024-10-24 Created: 2024-10-24 Last updated: 2024-12-18Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Westerlund, Jessica

Search in DiVA

By author/editor
Westerlund, Jessica
By organisation
School of Medical SciencesÖrebro University Hospital
In the same journal
Journal of Occupational and Environmental Hygiene
Occupational Health and Environmental Health

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 27 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf