Comparator Value Pairing Impacts Reported Continuous Glucose Monitoring System Accuracy Working Group on Continuous Glucose Monitoring, IFCC Scientific Division, Milano, Italy; Equalis AB, Uppsala, Sweden.
Working Group on Continuous Glucose Monitoring, IFCC Scientific Division, Milano, Italy; Department of Clinical Chemistry, Isala Clinics, Zwolle, the Netherlands.
Working Group on Continuous Glucose Monitoring, IFCC Scientific Division, Milano, Italy; Independent, Lampertheim, Germany.
Working Group on Continuous Glucose Monitoring, IFCC Scientific Division, Milano, Italy; Diabetes Research Institute, Mills-Peninsula Medical Center, San Mateo, CA, USA.
Working Group on Continuous Glucose Monitoring, IFCC Scientific Division, Milano, Italy; Shanghai Key Laboratory of Diabetes Mellitus, Department of Endocrinology and Metabolism, Shanghai Diabetes Institute, Shanghai Clinical Center for Diabetes, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Working Group on Continuous Glucose Monitoring, IFCC Scientific Division, Milano, Italy; Clinical Biochemistry Department, KAT General Hospital, Athens, Greece.
Working Group on Continuous Glucose Monitoring, IFCC Scientific Division, Milano, Italy; Dr. Mohan's Diabetes Specialities Centre & Madras Diabetes Research Foundation, Chennai, India.
Working Group on Continuous Glucose Monitoring, IFCC Scientific Division, Milano, Italy; Vanderbilt University Medical Center, Nashville, TN, USA.
Working Group on Continuous Glucose Monitoring, IFCC Scientific Division, Milano, Italy; Birmingham Women's and Children's Foundation Trust, Birmingham, United Kingdom.
Working Group on Continuous Glucose Monitoring, IFCC Scientific Division, Milano, Italy; Johns Hopkins Bloomberg School of Public Health, Baltimore, MD, USA.
Working Group on Continuous Glucose Monitoring, IFCC Scientific Division, Milano, Italy; Independent, Pirna, Germany.
Working Group on Continuous Glucose Monitoring, IFCC Scientific Division, Milano, Italy; Department of Pathology and Laboratory Medicine, University of California Davis Health, Sacramento, CA, USA.
Working Group on Continuous Glucose Monitoring, IFCC Scientific Division, Milano, Italy; Department of Diabetes, Endocrinology, Nutritional Medicine and Metabolism, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland; Diabetes Center Berne, Bern, Switzerland.
Institut für Diabetes-Technologie, Forschungs- und Entwicklungsgesellschaft mbH an der Universität Ulm, Ulm, Germany.
Show others and affiliations
2025 (English) In: Journal of Diabetes Science and Technology, E-ISSN 1932-2968, Vol. 19, no 5, p. 1423-1426Article in journal, Letter (Other academic) Published
Place, publisher, year, edition, pages Diabetes Technology Society , 2025. Vol. 19, no 5, p. 1423-1426
Keywords [en]
CGM performance, accuracy, continuous glucose monitoring, standardization
National Category
Endocrinology and Diabetes
Identifiers URN: urn:nbn:se:oru:diva-121219 DOI: 10.1177/19322968251344303 ISI: 001494160300001 PubMedID: 40405604 Scopus ID: 2-s2.0-105005842400 OAI: oai:DiVA.org:oru-121219 DiVA, id: diva2:1960664
Note Funding Agency:
Diabetes Center Berne
2025-05-232025-05-232025-09-08 Bibliographically approved