Sambandet mellan kontrastmedelsdos och kontrastattenuering vid fotonräknande datortomografi
Örebro University, School of Health Sciences.
2026 (Swedish)Independent thesis Advanced level (degree of Master (One Year)), 10 credits / 15 HE creditsStudent thesisAlternative title
Relationship between contrast mediadose and contrast attenuation in photoncounting computed tomography (English)
Abstract [sv]

Bakgrund: Fotonräknande datortomografi (PCCT) är en ny DT-teknik med förbättradkontrastupplösning, hög spatial upplösning och inbyggd dubbelenergiinformation, vilket gerpotential för kontrastmedelsoptimering. Eftersom kontrastattenuering påverkas av flerapatient-, kontrastmedels- och teknikrelaterade faktorer kan direkta jämförelser av absolutaHounsfieldenheter (HU) vara svåra att tolka. Det saknas kliniska studier som undersökersambandet mellan kontrastmedelsdos och kontrastattenuering vid PCCT, samt hurdosnormaliserade mått påverkas av olika kontrastmedelsdoser och val av monoenergetiskarekonstruktioner.

Syfte: Syftet med studien var att undersöka sambandet mellan kontrastmedelsdos ochkontrastattenuering vid fotonräknande datortomografi samt att analysera dendosnormaliserade upptagsfaktorn (Y) i olika organ vid olika kontrastmedelsdoser och vid tvåmonoenergetiska rekonstruktioner.

Metod: Studien genomfördes som en retrospektiv kvantitativ studie där 48 patienterinkluderades. Samtliga patienter hade genomgått två kontrastförstärkta DT-undersökningarmed olika kontrastmedelsdoser. Kontrastattenuering mättes i lever, pankreas, aorta och njurarvid monoenergetiska rekonstruktioner motsvarande ME45 och ME60. Den dosnormaliseradeupptagsfaktorn (Y) beräknades genom att normalisera kontrastförstärkningen tilladministrerad mängd jod. Statistisk analys utfördes med parat t-test och linjär mixad modell.

Resultat: Högre kontrastmedelsdos gav högre absoluta HU-värden i samtliga undersöktaorgan. Lägre energinivåer gav generellt högre HU-värden jämfört med högre energinivåer.Den dosnormaliserade upptagsfaktorn (Y) uppvisade däremot ingen statistiskt signifikantskillnad mellan låg och hög kontrastmedelsdos. Tydliga skillnader observerades mellan organ,där njurar och aorta uppvisade högre Y-värden än lever och pankreas. Resultaten från detparade t-testet och den linjära mixade modellen var samstämmiga.

Slutsats: Resultaten indikerar att upptagsfaktorn (Y), normaliserad till gram jod, är relativtstabil över de undersökta kontrastmedelsdoserna och att variationen främst påverkas avorganspecifika egenskaper. Upptagsfaktorn (Y) kan därmed ha potential som ett kvantitativtmått för framtida modellbaserad kontrastmedelsoptimering vid fotonräknande datortomografi.

Abstract [en]

Background: Photon-counting computed tomography (PCCT) is a novel CT technology with improved contrast resolution, high spatial resolution, and built-in dual-energy information, creating potential for contrast media optimization. Since contrast attenuation is influenced by several patient, contrast media, and technique-related factors, direct comparisons of absolute Hounsfield units (HU) values may be difficult to interpret. However, there is a lack of clinical studies investigating the relationship between contrast media dose and contrast attenuation in PCCT, as well as how dose-normalized measures are affected by different contrast media doses and the choice of monoenergetic reconstructions.

Aim: The aim of the study was to investigate the relationship between contrast media doseand contrast attenuation in photon-counting computed tomography, and to analyze the dose normalized uptake factor (Y) in different organs at varying contrast media doses and using monoenergetic reconstructions at two different energy levels.

Method: The study was conducted as a retrospective quantitative study including 48 patients. All patients had undergone two contrast-enhanced CT examinations with different contrastmedia doses. Contrast attenuation was measured in the liver, pancreas, aorta, and kidneys using monoenergetic reconstructions corresponding to ME45 and ME60. The dose normalized uptake factor (Y) was calculated by normalizing contrast enhancement to the administered amount of iodine. Statistical analysis was performed using paired t-tests and alinear mixed model.

Results: Higher contrast media doses resulted in higher absolute HU values in all examined organs. Lower energy levels generally produced higher HU values compared with higher energy levels. However, the dose-normalized uptake factor (Y) showed no statistically significant difference between low and high contrast media doses. Clear inter-organ differences were observed, with the kidneys and aorta demonstrating higher Y-values than the liver and pancreas. The results from the paired t-tests and the linear mixed model were consistent.

Conclusion: The results indicate that the uptake factor (Y), normalized to grams of iodine, is relatively stable across the investigated contrast media doses and that the variation is primarily influenced by organ-specific characteristics. The uptake factor (Y) may therefore have potential as a quantitative measure for future model-based contrast media optimization in photon-counting computed tomography.

Place, publisher, year, edition, pages
2026.
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:oru:diva-130084OAI: oai:DiVA.org:oru-130084DiVA, id: diva2:2087025
Subject / course
Medicine
Supervisors
Examiners
Available from: 2026-07-17 Created: 2026-07-17 Last updated: 2026-07-17Bibliographically approved

Open Access in DiVA

fulltext(418 kB)14 downloads
File information
File name FULLTEXT01.pdfFile size 418 kBChecksum SHA-512
a2093041e7e8a5efb73b55b8d93f110d65b4d7333e630c667f1f9520913f2bdf817f95e6ec0c635cb190e5909109a5cf5b9b4404ec07377a7921131535ab268f
Type fulltextMimetype application/pdf

By organisation
School of Health Sciences
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 53 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf